CCTV requirements in Qatar
A summary of the key requirements of the MOI Security Systems Department, with the official documents as published by the Ministry. The official documents and the Ministry’s latest releases are the binding reference.
Legal basis
- Law No. 9 of 2011Regulating the use of security surveillance cameras and devices.
- Minister of Interior Decision No. 11 of 2013Setting the technical specifications of surveillance cameras and devices, and where they are placed and installed.
- Council of Ministers Decision No. 4 of 2022Listing the facilities covered by Law No. 9 of 2011.
Key technical requirements
Numbers refer to the clauses of Annex 1 of the Technical Specifications, v1.0.
IP network system
The system must be an open standard based on Internet Protocol (IP).
120 days of recording
Enough storage to keep all recordings for 120 days in MPEG-4, H.264 or better compression.
Megapixel minimum
The minimum recommended camera resolution is megapixel.
Vandal and weather proof
Cameras must be vandal proof, tamper proof, weatherproof and day/night.
Target size on screen
Identification 120% of screen height, recognition 50%, detection 10%, monitoring 5%.
Number plate recognition
The plate should cover at least 50% of the screen height.
Tamper-proof recordings
Recordings must be tamper proof with an audit trail, and time-synced via NTP.
UPS for at least 1 hour
UPS backup must run the whole system for at least one hour in a power cut.
Hot standby
A hot standby system with automatic changeover on any fatal failure.
Maintenance contract
A corrective and preventive maintenance contract or SLA, with cleaning, repairs, software updates and maintenance logs.
The specifications also include annexes on camera locations for each facility type:
- Hotels, hotel apartments and residential complexes
- Banks, exchange houses and gold shops
- Sports and cultural clubs
- Shopping and entertainment centres
- Hospitals and clinics
- Warehouses and stores of hazardous or precious items
- Fuel stations
Is your facility required to install CCTV?
Facilities listed in the table attached to Council of Ministers Decision No. 4 of 2022 (54 types). Search for your facility type:
- 1Commercial agencies
- 2Tailoring workshops
- 3Petrol stations
- 4Outdoor hydrocarbon distribution stations
- 5Showrooms for goods or services
- 6Pharmacies
- 7Self-service machines
- 8Plants extracting, refining or processing natural resources (oil, gas, water, stone, cement)
- 9Petroleum and gas laboratories
- 10Gas filling plants and distribution
- 11Major oil, gas and water tanks
- 12Offshore oil and gas platforms and export facilities
- 13Printing presses
- 14Lathe workshops
- 15Car paint shops
- 16Precious metal smelting and goldsmith shops
- 17Car service stations
- 18Any other industrial facility, even if combined with farming
- 19TV and radio broadcasting stations
- 20Construction, renovation and demolition contractors
- 21Business, travel, import/export, customs clearance and recruitment offices
- 22Auction houses
- 23Public utility concession outlets (water, power, gas, post, telephone)
- 24Restaurants
- 25Cafés
- 26Massage centres (except women-only)
- 27Private and government educational institutes
- 28Kindergartens and nurseries
- 29Government and private schools
- 30Wedding halls (except women-only)
- 31Sports and racing venues and clubs
- 32Foundries and metal working shops
- 33Blacksmith, panel beating and lathe workshops
- 34Carpentry workshops
- 35Car and engine repair workshops
- 36Battery repair and charging workshops
- 37Electrical appliance repair workshops
- 38Producers of malodorous materials
- 39Organic fertiliser producers
- 40Electric, acetylene or oxygen welding shops
- 41Glass working shops
- 42Charcoal shops and stores
- 43Eyeglass lens grinding shops
- 44Car wash and lubrication shops
- 45Livestock pens and markets
- 46Warehouses and stores of all kinds
- 47Driving schools
- 48Computer programming and systems shops
- 49Transport businesses (car rental, limousine, public transport, shipping)
- 50Ports and marinas
- 51Public transport stations and vehicles
- 52Public transport stops
- 53Airports
- 54Trains, metro and tram
Unofficial English translation. The Arabic text is the official reference.
Your facility type is not in the list. Contact us and we will check which requirements apply.